The Check-Line TI-CMX accurately measures coating and wall thickness on a wide range of materials. Five selectable measuring modes enable the operator to precisely measure wall thickness, coating thickness and locate corrosion and pitting—without removing the coating.
Oversized graphic LCD is backlit and features an easy to navigate menu allowing quick access to gauge settings and options.
Five user-selected operating modes are included:
Coating On: Measures wall thickness using Pulse-Echo. It separately displays wall & coating thickness.
Coating Off: Measures wall thickness using Pulse-Echo. It displays wall thickness only.
Temperature Compensated: Measures wall thickness using Pulse-Echo and automatically adjusts calibration to compensate for changes in material temperature.
Thru-Coat: Measures wall thickness only using Echo-Echo. (coating is NOT included)
Coating Only Mode (CT): (Coating Thickness) Measures from 0.0005 to 0.100 inches (0.013 to 2.540 mm). Range will vary slightly depending on the coating.
Includes NIST-Traceable Calibration Certificate
Auto probe recognition with Auto Zero or Manual Zero.
Wide variety of dual-element probes can be used for nearly any application.
Bar graph with user-set start end values providing highest resolution around the target thickness value.
Differential Mode allows user to set a "target thickness value" and display will show the DIFFERENCE between actual and target thickness as a plus or minus value.
TI-CMX-H for surface temps up to 300°F/150°C. Optional hi-temp probes for higher surface temperatures offered
Adjustable Gain in 5 steps (VLow, Low, Med, Hi & VHi) in 2db increments providing a 8 db gain adjust range (42–50 db).
64 custom setups can be stored and retrieved for convenient use and labeled for easy identification
Display Hi/Lo Alarm Limits with audible and visual indicators.
2 Year Warranty & CE-Certified
Metal housing provides strong protection against harsh environments.
Measures Coatings up to 0.100"
IP 65 Rated
Range in Steel: | Pulse-Echo Mode: Pit and Flaw detection measures from 0.025 - 9.999inches (0.63 to 254 millimeters) |
Range in Coating Only Mode | 0.0005" - 0.1000" / Resolution: 0.0001" |
Max Coating | 0.100" (2.54mm) |
Resolution: | .001 inches (0.01mm) |
Velocity Range: | .0492 to .3936 in./ms |
Units: | Inch or mm |
Measurement Modes: | - Pulse-Echo (corrosion mode) |
Transducer Types: | Dual Element (1 to 10 MHz). |
Output | RS-232 for upload/download of setups |
Memory capacity: | TI-CMX: None |
Power Source: | Three 1.5V alkaline or 1.2V NiCad AA cells |
Battery Life: | Typically operates for 150 hours on alkaline and 100 hours on NiCad |
Auto Power off: | After 5 minutes of non-use |
Display: | 1/8 in. VGA grayscale display 62 x 45.7mm |
Keyboard: | Membrane switch with twelve tactile keys |
Case: | Extruded aluminum body with nickel-plated aluminum end caps (gasket sealed). |
Temp. Limits | Ambient: -20 to 120° F (-30 to 50° C) |
Weight, net: | 383 grams |
Dimensions: | 63.5 W x 165 H x 31.5 D mm |
Warranty: | 2 year limited |
Certification: | CE Approved, Factory calibration traceable to national standards |
订货清单
The Checkline TI-CMX is supplied as a complete kit with the gauge, probe, 4 oz. bottle of coupling fluid, 2 AA batteries, NIST-Traceable Calibration Certificate, operating manual, Software, RS-232 output cable, RS-232 to USB adapter, all in a foam-fitted carrying case.
配件
TICC-MVX Protective Holder for TI-MVX, TI-PVX and TI-MMX-SDL
V-Block V-Block Transducer Holder (For 3/16" & 1/4" Transducers only)
CF12 Coupling Fluid - 12oz
CF-4H High Temp Coupling Fluid 4oz (0 - 600 F / -18 to 316 C)
CF-4H-950F High Temp Coupling Fluid 4oz (600 - 950 F / 316 - 510 C)
T-102-2900 1/4" diameter, 5.00 MHz Coating Probe (Standard Probe for TI-CMX)
T-104-2900 1/2" diameter, 5.00 MHz Coating Transducer
T-104-9900 1/2" diameter, 3.5 MHz Coating Transducer
T-102-2900-H 1/4" 5Mhz Coating Transducer for Material Temp up to 300 °F (150 °C)
T-101-2900 3/16" diameter, 5 MHz Coating Probe
T-101-3900 3/16"-7.5MHz Coating Transducer
T-212-2001 1/4", 5 MHz Hi-Temp (900 F / 500 C) Transducer
TI-CMX-UW-50 1/2" 5 Mhz Hi Damp Coating Probe with 50 ft. underwater cable
BATT-RC4AA-WC 4-pack 2300mAh AA Ni-MH Rechargeable Batteries & Charger Kit
订货型号
TI-CMX Combination Coating & Wall Thickness Gauge kit with T-102-2900 probe
TI-CMX-H Combination Coating & Wall Thickness Gauge with T-102-2900-H High Temp Probe, up to 300 F (150 °C)
相关型号
TICC-MVX
SB-Series
SB4
CF-12
CF-2H
CF-4H-950F
V-Block
TI-CMX-UW-50