Maxxis 4 过程控制器


概述工业中的过程控制是指以温度、压力、流量、液位和成分等工艺参数作为被控变量的自动控制。就一般而言,管理中采取的控制可以在行动开始之前、进行之中或结束之后进行,称为三种控制模型。第一种称为前馈控制或预先控制,第二种称为过程控制或同期控制,第三种称为反馈控制或事后控制。

 

德国Sartorius Maxxis 4是一款可自由编程的过程控制器,专为各种简单称重应用中手动和自动配料以及填充系统而设计。连通性广,可兼容所有的模拟和数字称重传感器,台秤,地磅和更多称重方案。

The freely programmable process controller, designed for applications as diverse as simple weighing complex manual and automatic Batching and single component Filling. Maxxis 4 extensive connectivity options and compatibility with all analogue load cells and the digital Pendeo® load cells as well as platform scales and many more weighing solutions.


  • Process Controller for the automated control of weighing processes with one scale (analog or digital)

    连接一台秤(数字或模拟)进行称重过程的自动控制

  • Wide range of opportunities for flexible integration such as option cards

    DAT, multilingual easy operation interface, backup function, service reports, simulation. With an additional licence: OPC server, tilt correction

    数字辅助技术,操作方便,具有备份,服务报告、模拟等功能

  • Supplied with Ethernet TCP/IP, Modbus TCP, RS232, USB 1.1, SD-Card

    可连接各种接口,例如Ethernet TCP/IP、RS232、USB 1.1、SD卡等

    Several predefined software applications available:

    BASIC - for simple weighing applications

    IBC – for single component filling applications

    BATCH – for complex manual and/or automatic batching applications

    PHASE – for PC based recipe management software e.g. ProBatch+

    基本版本带有称重、检重和远程终端功能,还可选择IBC、BATCH或者PHASE应用程序


Load cell connection

All strain gauge load cells;

6- or 4-wire connection

Load cell supply

12 V, short-circuit proof.

External load cell supply possible.

Minimum load impedance

min. 75 Ohm

e.g. 6 load cells with 650 Ohm

or 4 load cells with 350 Ohm

Measuring principle

Measuring amplifier:

Delta-Sigma converter

Measuring time:

min 5 ms – max. 1600 ms

Digital filter for load cell

4th order (low pass), Bessel, Aperiodic

or Butterworth

A | D Converter Input range

4,8 nV (appr. 7.5 Mio. div.)

Usable resolution: 0.2 μV/d

Measuring signal: 0 to 36 mV

(for 100% nominal load)

Linearity

< 0.002%

Power Supply

100 – 240 VAC, (+10/–10%),

50 – 60 Hz max. 14 W/32 VA

Optional:

24 VDC, (+20/–10 %), max. 14 W

Temperature effects

Zero: TK0 m < 0,02 μV/K RTI

Span: TKspan < +/- 2 ppm/K

Environmental conditions

Temperature

Operation: –10°C to +50°C

Storage: –20°C to +70°C

Weight

Net: 2 kg

Shipping weight: approx. 3 kg


Maxxis 4

Maxxis 4 Process Controller, incl. Ethernet TCP | IP and Modbus TCP

1 × RS232, 1 × USB, 1 × SD Card

9405 155 00000

 

配件

Weighing Point Slot A

W1 A | D Converter 0

Housing

L14 Cable anchorage

L15 Mounting frame for the safe installation of the Maxxis 4 in cabinets with a wall thickness of less then 1.5 mm

Power Supply

L0 110 | 240 V AC power supply Standard

L8 24 V DC power supply

Applications and Licenses

H0 BASIC Application Standard

I4 PHASE Application (OPC included)

I6 BATCHING Application

I11 IBC – One Component Filling

I12 Tilt Correction License (Software BASIC needed)

E5 Alibi Memory License

E6 OPC Server License (AccessIt 2.0 included)

E9 Special License “Batch Modes” for using in individual programming

Interface Cards Slot 1 | 2

B15 | B25 Interface Card Serial 2 × RS485 (incl. supply for one IS Platform) 0 | 0

B16 | B26 Interface Card Analog 1 Input | 1 Output with 0/4 – 20 mA 0 | 0

B17 | B27 Interface Card Digital 4 Outputs Relay | 4 Inputs – active 0 | 0

B18 | B28 Interface Card Digital 4 Outputs Relay | 4 Inputs – passive 0 | 0

B19 | B29 Interface Card Digital 8 Outputs Optocoupler | 4 Inputs – passive 0 | 0

C21 Fieldbus Card Profibus DP - | 0

C24 Fieldbus Card DeviceNet - | 0

C25 Fieldbus Card CC-Link (Available 2015) - | 0

C26 Fieldbus Card Profinet - | 0

C27 Fieldbus Card Ethernet | IP - | 0


相关型号

PR 5500/00 Maxxis 4 process controller with Option:

A | D-converter (W1), 110 | 230 V (L0), BASIC-Application H0), Cable anchorage (L14)

9405 155 00001

PR 5500/01 Maxxis 4 process controller with Option:

A | D-converter (W1), 24 V (L8), BASIC-Application (H0), Cable anchorage (L14)

9405 155 00011

PR 5500/20 Maxxis 4 process controller with Option:

A | D-converter (W1), 110 | 230 V (L0), 6/8 digital I/O (B19), Batch-Applikation (I6),

Cable anchorage (L14)

9405 155 00201

PR 5500/21 Maxxis 4 process controller with Option:

A | D-Wandler (W1), 24 V (L8), 6/8 digitale E/A (B19), Batch-Applikation (I6), Zugentlastung (L14)

9405 155 00211

PR 5500/30 Maxxis 4 process controller with Option:

A | D-converter (W1), 110 | 230 V (L0), 6/8 digital I/O (B19), IBC-Application (I11),

Cable anchorage (L14)

9405 155 00301

PR 5500/31 Maxxis 4 process controller with Option:

A | D-converter (W1), 24V (L8), 6/8 digital I/O (B19), IBC-Applikation (I11), Cable anchorage (L14)

9405 155 00311

PR 5500/90 Maxxis 4 process controller with Option:

A | D-converter (W1), 110 | 230 V (L0), Phase-Application (I4), Cable anchorage (L14)

9405 155 00901

PR 5500/94 Maxxis 4 process controller with Option:

A | D-converter (W1), 24V (L8), Phase-Application (I4), Cable anchorage (L14)

9405 155 00941

PR5500/10 A | D Converter 9405 355 00101

PR5500/04 Interface Card Serial 2 × RS485 (incl. supply for IS platform) 9405 355 00041

PR5500/12 Interface Card Digital 4 × Input | 4 × Output (active) 9405 355 00121

PR5500/13 Interface Card Digital 4 × Input | 4 × Output (passive) 9405 355 00131

PR5500/17 Interface Card Digital 8 Outputs Optocoupler | 4 Inputs (passive) 9405 355 00171

PR5500/07 Interface Card Analog 1 × Input | 1 × Output 0 | 4 – 20 mA 9405 355 00071

PR1721/61 Interface Card Profibus DP 9405 317 21611

PR1721/64 Interface Card DeviceNet 9405 317 21641

PR1721/65 Interface Card CC-Link (Available 2015) 9405 317 21651

PR1721/66 Interface Card Profinet 9405 317 21661

PR1721/67 Interface Card Ethernet | IP 9405 317 21671

PR5500/81 PHASE Application License 9405 355 00811

PR5500/83 BATCHING Application License 9405 355 00831

PR5500/86 IBC – One Component Filling License 9405 355 00861

PR5500/87 Tillt Correction License (Software BASIC) 9405 355 00871

PR5500/91 Alibi Memory License 9405 355 00911

PR5500/92 OPC Server License (AccessIt 2.0 included) 9405 355 00921

PR5500/93 Special License “Batch Modes” for Programming 9405 355 00931

 

Maxxis 5

MP30

X3 PR5410

X4 PR5510

X5 PR5610

X6 PR5710


Maxxis 4 01.png